3020
3020
Electromechanical Automatic Deadlocking Latch
Electric 24VDC solenoid power and manual key unlocking
Designed to mount in a standard 2" deep hollow metal frame face
Catalog Page with Technical Information:
(English)
UL Certificated
ASTM Standardized
10B, 3 Hour
"A"
(Grade 1)
F1450-97
F1577-01
Technical Notice
RRBLS 3020FS employs electronic circuitry to protect its push type solenoid from overheating and possible failure resulting from an inability for the plunger to seat fully under power (i.e. achieve deadlock status) due to external blockage of the deadbolt travel, which is usually caused by a misalignment of the 3020FS’s bolt and/or keeper. In the event the solenoid plunger does not seat fully within 2 - 3 seconds after door lock actuation, as can be indicated remotely by an unsecure signal (e.g. red light and/or audible alarm), a power circuit reset becomes necessary to effect proper deadlocking. This requires (1) switching off the lock’s power (i.e. enabling bolt retraction), (2) opening the door, (3) correcting the cause of the blockage and (4) reclosing and powering the 3020FS until a secure (aka deadlocked) lock status indication (e.g. green light) is reliably attained.